Home / Glossary
Glossary 69 terms, A to Z
Concrete scanning words, in plain terms
The words you meet on a drawing, a scan or a scanning report, from back wall to two-way travel time. Short definitions, a link to the guide that goes deeper, and a numbered source wherever there is a number or a rule.
A
- 01Anchoralso Post-installed anchor
A fixing set into a drilled hole: an expansion anchor, a screw anchor or a bonded (resin) anchor. Check where the hole goes and also how deep: see embedment depth.
ReadDrilling into concrete safely You hit rebar. What now?- 02Anchor pocketalso Stressing pocket
The recess at a slab edge or soffit where a post-tensioning tendon is anchored and later patched. Penhall lists anchor pockets, end caps and tendon blisters as signs of a post-tensioned slab, but warns they can be patched over, removed or absent1.
ReadDrilling into a post-tensioned slab- 03Antenna frequency
The frequency at which a radar sends its pulses. Higher frequency gives a sharper picture but less depth; lower frequency sees deeper with less detail2. GSSI's concrete handbook covers antennas of 1.6, 2.0 and 2.6 GHz3.
ReadGPR, wall detector or pocket scanner- 04As-built drawingsalso Record drawings
Drawings updated to show what was really built, not only what was designed. They are the best first source for bars, tendons and services, and still not a clearance: check on site.
ReadDrilling into concrete safely
B
- 05Back wall reflectionalso Backwall
The echo from the far side of a wall or slab. It is not a single point, so it shows as a flat band across the picture, not as a hyperbola2. It tells you the thickness, and so how long your bit can be. Eagle XR's listed targets include the back of the element4.
ReadHow to read a concrete scan- 06Blockworkalso CMU (concrete masonry unit)
Walls built from concrete blocks. Hollow blocks have open cells; some cells are filled with grout and a bar, others stay empty, so a drill can break into a void.
ReadDrywall, brick and block- 07Bonded and unbonded tendons
Two kinds of post-tensioning. A bonded tendon runs in a duct that is filled with grout after stressing; an unbonded tendon is a single strand in a greased plastic sheath. Both stay under load for the life of the slab.
ReadDrilling into a post-tensioned slab
C
- 08Calibration (depth)
Setting the radar's wave speed for the concrete in front of you, on a known depth or from the shape of a hyperbola. GSSI warns that an assumed concrete type can put the depth off by as much as 20%3.
ReadHow to read a concrete scan- 09Chase
A slot cut into a wall or floor to bury a cable or pipe, then filled over. Once plastered, an old chase is invisible, so look for it on drawings and scans.
ReadDrywall, brick and block- 10Conduit
A tube, metal or plastic, that cables are pulled through. Conduits are often cast into slabs. Eagle XR's App Store listing names electric cables and conduits among its targets5.
ReadDrilling into concrete safely- 11Core drillingalso Coring
Cutting a round hole with a hollow diamond bit, usually water cooled. A core bit cuts through steel in its path, so the scan must cover the whole circle plus a margin.
ReadCore drilling checklist- 12Coveralso Concrete cover
The concrete between the surface and the nearest bar. Codes set a minimum cover to protect the steel, so the drawings tell you how deep the first bar should be. Site reality varies.
ReadHow deep is rebar?- 13Cover meteralso Covermeter, rebar locator
A hand tool that finds steel bars with an electromagnetic field and estimates their cover. Cover meters are typically sensitive to all metal in range of their probe, and congested, lapped or doubled bars interfere with the reading6. They do not see plastic pipes.
ReadGPR, wall detector or pocket scanner Compare the tools- 14Cross-polarisation
Turning the radar antenna so that more energy passes beside the bars. The bars show with shorter tails and the back wall can come through cleaner2.
ReadHow to read a concrete scan
D
- 15Depth of penetration
How deep a scanner can still see. Wet concrete, poor concrete and dense steel all cut it2. Screening Eagle puts the physical limit of concrete GPRs at somewhere around 60 to 80 cm7 and states 40 cm depth in concrete for Eagle XR4.
ReadGPR, wall detector or pocket scanner Compare the tools- 16Dielectric constantalso Relative permittivity
A number for how a material slows a radar wave. Radar reflects where it changes. Screening Eagle gives concrete typically 7 to 12, air 1, plastic about 4 and water 812. The higher the number, the slower the wave3.
ReadHow to read a concrete scan How it works- 17Drapealso Tendon profile
The curved path of a post-tensioning tendon through the slab. Tendons usually sit high over supports and low at midspan, while rebar stays at a constant depth8. So a tendon's depth depends on where you are.
ReadDrilling into a post-tensioned slab- 18Duct
The tube that holds the strands of a bonded tendon. It is filled with grout after stressing. Eagle XR's App Store listing names PT ducts among its targets5.
ReadDrilling into a post-tensioned slab
E
- 19Eddy current
The method most cover meters use: a coil makes a changing magnetic field and metal nearby disturbs it. Screening Eagle describes cover meters as eddy current technology, designed for steel bars9.
ReadGPR, wall detector or pocket scanner- 20Edge distance
How far an anchor sits from a slab edge, an opening or another anchor. The anchor maker sets minimums, so moving a hole away from a bar must not bring it too close to an edge.
ReadYou hit rebar. What now?- 21Embedment depth
How deep an anchor goes into the concrete. Compare it with the depth of bars and tendons, not only their position on the surface.
ReadDrilling into a post-tensioned slab- 22Engineer of recordalso EOR
The engineer responsible for the structural design. Whether a bar or tendon may be cut, or a hole moved into a zone, is their decision, not the driller's.
ReadYou hit rebar. What now?
F
- 23Fibre-reinforced concretealso FRC, SFRC
Concrete with short steel or polymer fibres mixed all through it. Steel fibres make radar pictures blurry, with strong reflections near the surface9. See steel fibre.
ReadFibre-reinforced concrete- 24Flutealso Trough
One corrugation of a profiled steel deck. Hilti speaks of upper and lower flutes, and notes that installers often cannot tell where they are when looking down on the slab10. The concrete is thinnest over the upper flutes.
ReadMetal deck slabs
G
- 25GPRalso Ground penetrating radar
Ground penetrating radar. It sends short radio pulses into the material and records the echoes from boundaries between materials2. For investigations, mapping and reports, professionals use GPR systems; Screening Eagle says Eagle XR is not one4.
ReadGPR, wall detector or pocket scanner Compare the tools- 26Green concretealso Fresh concrete
Concrete that is still young and wet. Screening Eagle says GPR should not be used on fresh concrete, as it is significantly limited until the concrete is fully cured2.
ReadHow to read a concrete scan- 27Grid scan
Scan lines in two directions at right angles over the spot. A radar mostly detects metal objects roughly perpendicular to the scan line3, so the second direction catches what the first missed.
ReadHow to use Eagle XR- 28Grouted cell
A cell in a hollow block wall that has been filled with grout, often with a vertical bar. The empty cells next to it are voids.
ReadDrywall, brick and block
H
- 29Hollow-core plankalso Hollowcore slab
A precast floor unit with voids, called cores, running through its length11. Its strength is in prestressing strand, so plank makers tell trades to drill through the core locations12.
ReadHollow core and precast- 30Honeycombing
Pockets in concrete where the paste did not fill between the stones. Screening Eagle names honeycombing among the kinds of air inside concrete that radar can show2.
ReadHow to read a concrete scan- 31Hyperbola
The arch shape a bar, pipe or cable makes on a radar picture. The echo arrives soonest when the antenna is right above the object, which forms the peak2. The object sits under the peak.
ReadHow to read a concrete scan How it works
L
- 32Lapalso Lap splice
Where two bars overlap so that one passes its load to the next, often tied together. Lapped and doubled bars interfere with cover meter readings6.
ReadHow deep is rebar?- 33Line scan
One pass of the scanner along a line, giving one slice through the element. Eagle XR scans one line at a time, in one direction (our own use of a unit).
ReadHow to use Eagle XR Scan lab- 34Live cable detectionalso AC detection
Some wall detectors also sense the electric field of a live mains cable. A scan picture shows where a cable is, not whether it is live. Screening Eagle's pages do not say whether Eagle XR tells a live cable from a dead one, so treat every cable as live.
ReadDrywall, brick and block
M
- 35Macro-synthetic fibre
A polymer fibre long and stiff enough to carry load after the concrete cracks, developed as an alternative to steel fibres in some uses13. It is not metal.
ReadFibre-reinforced concrete- 36Matalso Top mat, bottom mat
One layer of bars running in both directions. Slabs and walls often have two mats, one near each face. The first mat can hide the second: see rebar shadow.
ReadHow deep is rebar?- 37Meshalso Welded fabric, WWF
Bars or wires welded into a grid and delivered in sheets, common in slabs, toppings and screeds. GSSI's handbook says a fine mesh (5 x 5 cm or smaller) acts like sheet metal to radar: nothing beneath it shows3.
ReadHow deep is rebar?- 38Metal deckalso Steel deck, pan deck
Corrugated steel sheet that is the formwork for a concrete floor and then works with the concrete as reinforcement14. Radar cannot pass a continuous metal layer, and SPH Engineering calls concrete on metal decks generally opaque to GPR15.
ReadMetal deck slabs- 39Micro-synthetic fibre
Short, thin, chopped polypropylene fibres added at about 0.9 kg/m³, mainly to change the fresh concrete. They are not counted in design and can be used along with steel fibres13.
ReadFibre-reinforced concrete- 40Migration
A processing step that uses the shape of each hyperbola to work out the wave speed in the concrete3, which then sets the depth scale.
ReadHow to read a concrete scan
P
- 41PAS 128
A BSI specification for detecting, verifying and locating underground utilities; the current edition is PAS 128:202216. It sorts survey results into quality levels. It is about pipes and cables in the ground, not inside a slab.
ReadConcrete scanning standards- 42Permittivity
Relative permittivity is another name for the dielectric constant2. Same number, same meaning for a scan.
ReadHow to read a concrete scan- 43PEX
Cross-linked polyethylene pipe, used for water supply and underfloor heating. It is plastic, so a metal detector will not find it. Eagle XR's listing names non-metallic PEX and PVC water pipes among its targets5.
ReadFinding plastic pipes- 44Post-tension tendonalso PT cable, tendon
High-strength steel strand pulled tight after the concrete has hardened and locked off at anchors at the slab edges. It carries much of the slab's load. Never drill near one without the engineer and a specialist scan.
ReadDrilling into a post-tensioned slab- 45Post-tensioned slabalso PT slab
A slab held in compression by tendons. Trinity Subsurface notes PT is common in parking garages, high-rise residential, offices and hospitals, and advises treating a slab as post-tensioned until a scan shows otherwise8.
ReadDrilling into a post-tensioned slab- 46Precast
Concrete elements cast in a factory and lifted into place: planks, beams, wall panels, stairs. What is inside depends on the maker's drawings, so ask for them.
ReadHollow core and precast- 47Prestressedalso Pretensioned
Concrete put into compression by tensioned steel. In pretensioned precast units the strands are tensioned before casting; in post-tensioned work after.
ReadHollow core and precast Drilling into a post-tensioned slab- 48PVC
A rigid plastic used for pipes and conduit. GSSI calls PVC nearly transparent for radar: "we do not directly detect the PVC, we detect whatever is inside"3. A filled pipe is easier to find than an empty one.
ReadFinding plastic pipes
R
- 49Radargram
The picture a GPR makes: distance along the scan line across, time or depth down. Screening Eagle uses this name for a typical GPR image with rebar and a back wall2.
ReadHow to read a concrete scan- 50Rebaralso Reinforcing bar
Ribbed steel bar cast into concrete to carry tension. It runs in layers called mats in slabs and walls, and as main bars and stirrups in beams and columns.
ReadHow deep is rebar?- 51Rebar shadow
What a bar hides beneath it. Metal reflects all of the radar energy, so nothing below it is seen2. GSSI adds that a target directly beneath another may or may not be seen3.
ReadHow to read a concrete scan- 52Resolution
How small or close together things can be and still show separately. For a 1.6 GHz antenna in concrete, SPH Engineering gives a minimum detectable target of roughly 35 to 40 mm near the surface, growing with depth15.
ReadHow to read a concrete scan How it works
S
- 53Screed
A levelling layer laid on a concrete slab, often holding underfloor heating pipes. Drill a heated screed only after you know where the loops run.
ReadFinding plastic pipes- 54Sheath
The plastic sleeve around a single unbonded tendon, with grease inside, so the strand can move when stressed.
ReadDrilling into a post-tensioned slab- 55Slab on gradealso Ground-bearing slab
A concrete slab cast directly on the ground. You can only scan it from the top, and services often run in the ground beneath it.
ReadDrilling into concrete safely- 56Slicealso Virtual slice
A cut-away picture of what is under one scan line, from the surface down. Screening Eagle's illustration of Eagle XR shows a virtual slice with a depth axis from 0 to 40 cm4.
ReadHow it works How to use Eagle XR- 57Soffit
The underside of a slab, beam or stair. Overhead anchors go into the soffit, and that is where the bottom bars and low tendons are closest.
ReadDrilling into a post-tensioned slab- 58Steel fibre
A short piece of steel wire mixed into concrete. The most common lengths are 35 to 60 mm and diameters 0.5 to 1.0 mm13. On radar the fibres give strong reflections near the surface and a blurry picture9.
ReadFibre-reinforced concrete- 59Stirrupalso Link, tie
A closed loop of bar wrapped around the main bars of a beam or column, holding them in place. Stirrups repeat along the member, so a beam or column leaves little room for a hole.
ReadHow deep is rebar?- 60Strand
Several high-strength steel wires twisted together. It is the steel in post-tensioning tendons and in pretensioned precast such as hollow-core planks.
ReadDrilling into a post-tensioned slab Hollow core and precast- 61Stud
A vertical timber or metal post in a partition wall. Cables often run through or beside studs, so a stud detector finds the frame, not everything on it.
ReadDrywall, brick and block- 62Survey to a standard
A scan done to a named document and method, by a qualified operator, with a written report that states its limits. A pocket first-look scan is not that: Screening Eagle says that for investigations, mapping and reports, professionals use GPR systems4.
ReadConcrete scanning standards
T
- 63Tendon blister
A raised strip on a slab soffit that follows a draped post-tensioning tendon. Penhall lists it as a sign of a two-way PT slab, visible only on exposed soffits1.
ReadDrilling into a post-tensioned slab- 64Topping
A concrete layer cast over precast planks, or the concrete cast onto a metal deck. On hollowcore it may be a thin levelling coat or a structural layer; PCI's chapter gives a 3/4-inch levelling coat or a 2-inch topping as examples17.
ReadHollow core and precast Metal deck slabs- 65Two-way travel time
The time a radar pulse takes to reach an object and come back. The radar multiplies it by the wave speed to get depth3. For dielectrics of 3 to 12, GSSI gives speeds of 18 to 9 cm per nanosecond3.
ReadHow to read a concrete scan How it works
U
- 66Ultrasonic pulse echoalso UPE
Testing with sound waves instead of radio waves. It is good at finding air inside concrete and less good at metal, but Screening Eagle says it can find large post-tensioning ducts in steel fibre concrete with little interference from the fibres9.
ReadFibre-reinforced concrete- 67Underfloor heatingalso UFH
Loops of plastic pipe laid in a screed or slab, fed from a manifold. Scan with the system filled: radar sees what is inside a plastic pipe more than the plastic3.
ReadFinding plastic pipes
V
- 68Voidalso Air void
A pocket of air inside the concrete, or the empty core of a hollow block or plank. Air has a dielectric constant of 1, so its echo is weaker than metal's and rarely a clean arch2.
ReadHow to read a concrete scan
X
- 69X-rayalso Radiography
Radiography through concrete. It needs access to both sides of the element, a source on one side and film or a detector on the other15, and the area behind cleared.
ReadGPR, wall detector or pocket scanner
Ready to see inside your own slab?
CHF 3,950per scanner, excluding VAT, import taxes and delivery. Eagle XR pairs with your phone and shows rebar, cables, plastic pipes and air voids at their depth, up to a stated 40 cm in concrete. Ordering happens on Screening Eagle's shop.
Buy in Solar GoldPartner link: we may earn a commission. You pay Screening Eagle's normal price.
- Sold and shipped by Screening Eagle
- Same price in all four finishes
- Card, Apple Pay or Google Pay
- Express shipping from Switzerland. US orders ship from Pennsylvania
Sources
Each source was opened on 16 November 2026 and the statement found on it. Definitions without a number are our plain wording of common site terms. Eagle XR facts come from Screening Eagle's own pages, except the one line marked as our own use of a unit.
- Penhall, Post-Tension vs Rebar: How to Tell What You're Dealing With Before You Drill, read 16 November 2026, penhall.com
- Screening Eagle (Proceq), Uncovering the Hidden Secrets of Concrete: What GPR Can (and Can't) Reveal, read 16 November 2026, screeningeagle.com
- GSSI, Concrete Handbook MN72-367 Rev H, read 16 November 2026, atecorp.com
- Screening Eagle, Eagle XR product page and FAQ, read 16 November 2026, xr.screeningeagle.com
- Apple App Store, Eagle XR listing by Screening Eagle Technologies AG, read 16 November 2026, apps.apple.com
- PCTE (Australia), Cover Meter Operation Procedure, read 16 November 2026, pcte.com.au
- Screening Eagle Tech Hub, Evaluating Concrete Using Ultrasonic Tomography, read 16 November 2026, screeningeagle.com
- Trinity Subsurface, Scanning Post-Tension Slabs Before You Core or Cut, read 16 November 2026, trinitysubsurface.com
- Screening Eagle, application note: Detecting PT Ducts in Steel Fibre Reinforced Concrete (SFRC), read 16 November 2026, screeningeagle.com
- Hilti USA Engineering Center, Is it possible to check anchors on the top of a composite metal deck over high flutes, read 16 November 2026, hilti.com
- The Concrete Centre, Hollowcore slabs, read 16 November 2026, concretecentre.com
- Oldcastle Infrastructure, Elematic Hollowcore Plank 2019 Technical Data Guide, read 16 November 2026, oldcastleinfrastructure.com
- New Steel Construction (Steel Construction Institute), Use of fibre-reinforced concrete in composite slabs (part 1), January 2023, read 16 November 2026, newsteelconstruction.com
- STRUCTURE magazine, Natasha Zamani, Structural Considerations for Openings in Composite Floor Decks, read 16 November 2026, structuremag.org
- SPH Engineering, GPR Scanning in Concrete to Find Rebar, PT Cables and Voids, read 16 November 2026, sphengineering.com
- BSI Knowledge, PAS 128:2022 Underground utility detection, verification and location: Specification, read 16 November 2026, knowledge.bsigroup.com
- PCI, G/C PCI chapter, Hollowcore FAQs, read 16 November 2026, pci.org